Q:

f-10 code ? 79045489501 Kenmore Electric range

A:

Thank you for choosing Searspartsdirect.com and being a valued member. I can certainly assist you with the error code. 

F10 Runaway Temperature: 1.(F10 only) Check RTD Sensor Probe and replace if necessary.

If oven is overheating, disconnect power. If oven continues to overheat when the power is reapplied, replace EOC. Severe overheating may require the entire oven to be replaced, should damage be extensive.

You can also visit searpartsdirect.com for parts, diagrams, and repair information.

If you do not feel confident repairing this problem yourself, then you can have it repaired at your home by a Sears technician. Here is a link for the website: Sears Home Services .

Thank you for your question. Have a great day.

SAFETY NOTICE: Be sure to disconnect power to the appliance before performing any repairs. If you are not comfortable with doing any voltage checks that might be recommended, please contact your local service provider for repairs. Be aware that there could be sharp edges inside the appliance that could cause cuts or other injuries to yourself or others.

Read More
Natasha12 -
Sears Technician
July 08, 2015
A:
Natasha12 -
Sears Technician
July 08, 2015
See more answers
Q:

Need wiring diagram for Kenmore range

A:

Thank you for your question. I can understand your concern about wiring the new switch. I'm attaching the wiring diagram below. I hope this will help you. If you would like more assistance, reply to this thread and I will be glad to assist you further.

Read More
Scott D -
Sears Technician
October 25, 2013
A:

Thanks for the diagram. It makes sense, and would help a lot more if the old switch and the new switches were exactly the same. The Old switch has 5 electrical plugs that are all marked, and it looks like I see these wires on the diagram. marked as L2, H2, H, P, L. If I understand this correctly-- L2 gets the red wire, H2 gets a yellow wire, H gets a yellow wire, P gets 2 black wires, and L gets a black wire. The problem is that the new switch is a little different. It looks have the plugs in different locations and different markings. 1H1, 2P, 3L1, 5L2, 4H2. These are listed from the same order as I listed the ones on the old switch. Now my question is What wire goes to what plug?? Thanks for your help. Al

Read More
Al -
October 28, 2013
A:

Al, it looks like the terminals on the new switch are still marked the same as the original. Even if the terminals are in different positions, the wires will still go to the same termianls. H1 = yellow, P = 2 black wires, L1 = black, L2 = red and H2 = yellow. I hope this will help you.

Read More
Scott D -
Sears Technician
October 29, 2013
A:

Thank You, this will help.

Read More
Al -
October 30, 2013
A:

Al, thank you for using Manage My Life.

Read More
Scott D -
Sears Technician
October 31, 2013
See more answers
Q:

Kenmore Electric drop-in Range - Model #790.45489501

A:

Thank you for submitting your question. I understand your concern and I will be happy to assist you. If the range is not reaching the correct temperature or if the temperature is too high, that is an issue with the oven temperature sensor probe (316217002). If you have a ohms/volt meter you can test the probe to verify the part. The probe will be located in the cavity of the oven in the upper left or right hand corner. Remove the two mounting screws that are securing the probe to the back wall of the oven. NOTE: If you don't see any mounting screws on the inside of the oven cavity, then you will need to remove the back panel  of the range to access the probe. Slowly begin pulling the probe out until you come to a quick disconnect plug. Disconnect the probe plug and then insert one meter lead into the terminal of the probe plug and place the other meter lead into the other terminal of probe plug. Place the dial on your ohms/volt meter to 200K. The probe should measure 1091 ohms plus or minus 5.3 ohms at room temperature of 75 degrees plus or minus 2.5 degrees if it's okay. If it doesn't measure approximately 1091 ohms, replace the probe. If the oven probe measures correctly, then the issue will be with the main contraol board (318296802) and it'll need replaceent (third image). You can order parts from our Sears Parts Direct web site. I hope this helps. Please reply back to this thread if you require further assistance. Thank you for using Manage My Life.

Read More
Tykara -
Sears Technician
August 26, 2013