Question and Answers

Q:

Kenmore Sears gas-fired direct vent wall furnace. Model # 867736434

A:

Managemyife.com is about helping you save money by helping you with any repairs you feel comfortable doing on any product, like the Kenmore wall furnace.  For piece of mind and assured performance, it may be worth the $69.00.  While waiting for specific information on your specific model, I am providing a link to owners manual in case you do not have one.  We would like to restore your faith in Sears, thank you for your patience.

Read More
Anna T -
May 31, 2013
A:

Thank you for your question. I'm sorry you are having this problem with the furnace. First make sure the gas has been disconnected and the burner cannot come on. The best method of turning the fan off will be to turn the breaker off that supplies voltage to the furnace. If the breaker also supplies voltage to other products and can’t be left off, then what you can do is remove the front grill of the furnace and you will see a couple of discs. Disconnect the power again. Follow the wires from the motor and they should connect to these discs. Remove the wires and tape them off good and this will disconnect the motor. Now reconnect the power and replace the furnace grill. I hope this will help you. If you would like more assistance, reply to this thread and I will assist you further.  

If you do not feel confident repairing this problem yourself, then you can have it repaired at your home by a Sears technician. Here is a link for the website: Sears Home Services.

Read More
Scott D -
Sears Technician
June 04, 2013
A:

1. Can you provide the link to the owners manual? The one Anna T provided does not work. 2. Is this (Model # 867736434) a B-Vent unit? Or does it bring in outside air for combustion? I have the ability to buy a second hand one in good working order and considering using it to heat a 2.5 car garage. Please advise......Thanks!

Read More
Anonymous -
November 21, 2015
See more answers
Q:

Why is the compressor on my refrigerator suddenly louder than it was 795.6900

A:

Thanks for the inquiry and for being a valued member.

Compressors are not silent when operating. They should run with a monotonous drone. Knocking sounds coming from the compressor are cause for concern. A hum with no background compressor noise may indicate that the compressor is inoperative. No noise at all also indicates that the compressor isn't working.

Some vibration is common with any compressor. Compressors are mounted on rubber feet to isolate this vibration. Excessive vibration, often accompanied by unusual noise, is a sign of severe problems with the system.

Compressor noise and/or vibration may be the result of:

bad valves, pistons or bearings

a poorly secured compressor (e.g., a broken compressor mount)

slugging (trying to pump liquid Freon or oil)

Unusual noises often indicate imminent failure of the compressor. Excess vibration leads to joint failure in the Freon line connections. This will allow Freon loss which leads to compressor burnout. Internal damage may also be done to the compressor.

When the compressor is running, look for evidence of vibration. This can sometimes be seen through the condenser cover or through the coil. Intermittent vibration or vibration which is readily visible may indicate problems. Look at the rubber mounts to make sure they are secure. Don't worry about vibration on startup or shutdown. This is typical. However, a broken mount will show up clearly at startup and shutdown.

If you would feel more confident have a Sears Home Service technician help assist with the diagnosis/repair, you can call 1-800-469-4663, or click here to be directed to the page to set up service.

I hope this helps and thanks for using SearsPartsDirect.com.  

Read More
Jeff Wallace Sr -
Sears Technician
March 19, 2015
Q:

How can I purchase the exercise chart for a weider Pro 6900, model # 831.14922.0? 831149220 Weider Weider pro 6900

A:

Thank you for choosing SearsPartsDirect. I will be more than happy to assist you with your Weight system.  

From the information you have provided above, after researching your model number 831.14922.0. I have located the exercise guide chart. This can be ordered at SearsPartsDirect.com. Click here.  The part number is 201847.

I hope you found this information useful. Again thank you for choosing Sears, we appreciate your business, have a great day.

Read More
Benny23 -
Sears Technician
February 04, 2015
A:

Weider Pro 6900 Weight System, How can I buy add on weights, ie 2.5 lb, 5 lb weight plates for the model 6900. Greg

Read More
Greg -
February 08, 2015
See more answers