Q:

Dryer showing 120v per leg @ element, but only 120v together when tested @ load???

A:

I can understand you have some technical question on the dryer. Please provide the model number to get the best possible answer. Just click on reply to continue the thread. Expert response time may take two business days. Thanks for your patience. If you decide on service, that link is available below.

Read More
Anna T -
March 03, 2013
A:

Thanks for the reply Anna. Make: Roper Model: res6745pq0

Read More
david -
March 03, 2013
A:

I suspect you have a neutral problem.  The image below may be helpful.  If you get 120 volts from hot to neutral, black wire or red wire to white wire in center of terminal block but don't get 240 volts across you most likely ahve a neutral problem.  This will need to be repaired by a electrician. 

Read More
Fred M -
Sears Technician
March 04, 2013
A:

Hey Fred, I have 120 to each side & 240 across at the block, but not @ element. It will show 240 for a split sec. n drop back to 120 when measured across. I took apart the timer and the points look fine..... Could this be motor switch? or would I not get 120 at all on that leg if it was bad? Thanks for your help.... I'm losing my mind!

Read More
david -
March 04, 2013
A:

My apologies Fred... You're absolutely correct @ only 120v across the block. The line is running to a 40a breaker. Is that more than likely the culprit? Thanks again

Read More
david -
March 04, 2013
A:

Check the voltage across the block when the dryer is at rest and check again while the dryer is running and see if you get the same reading.

Read More
Fred M -
Sears Technician
March 05, 2013
A:

Hey Fred, I measured voltage @ the panel until I didn't have 240 anymore.... Which was pretty quick! 240 off the meter, then 120 off the lugs from main breaker. Pulled the city meter and tested continuity on main breaker... sure enough, one side was bad. The double breaker for the dryer was also sitting on one leg, not across both! Weird... This is an old Federal Pacific panel so a 100amp "Snap in" breaker was quite a bit!!! I actually had to go to 3 home depots to find one! lol . Thanks for your help

Read More
david -
March 06, 2013
A:

Remember to always use caution when checking live voltage but great job.

Read More
Fred M -
Sears Technician
March 07, 2013
See more answers
Q:

My elite Kenmore stove takes 40 minutes to reach setting temperature

A:

I can see how this issue would disappoint you. It is a great inconvenience when your oven isn't working properly. I researched your question and was able to find a couple helpful links that will provide information regarding this issue. I attached the links below. I hope this helps.

Read More
Jackie S -
March 18, 2012
A:

The links Jackie S sent give good information for testing the range.

I suspect the problem is in the bake burner or the bake ignitor. I suggest you remove the oven bottom and the flame spreader attached to the bake burner so you can see the flame on the bake burner. You can remove the oven bottom by removing the 2 screws on the rear corners. Lift the back of the oven bottom about 1-2 inches and slide it back.

If the oven burner is burning a normal size flame and is even all the way around, replace the bake ignitor. If the burner is burning very large flames in one or two areas, replace the bake burner. The part numbers and prices are:

22 628 316404400 1 44.05 79079364402 Burner,oven 22 628 316428500 1 67.45 79079364402 Ignitor,oven burner

You can order the parts at Parts Direct

If you have questions, reply on this thread and I will be glad to help.

Read More
Jimmy K -
Sears Technician
March 19, 2012
A:

When using the bake I noticed the ignitor stays on and the gas comes on and off every 30 seconds.

Read More
Bernard -
March 19, 2012
A:

Bernard, since the ignitor stays on, we know the control board is not turning the burner off. If the burner is burning evenly all the way around, I would replace the ignitor.

Read More
Jimmy K -
Sears Technician
March 20, 2012
A:

Does the ignitor control the gas to the flame? It seems like the ignitor stays on and the gas comes on and off every 30 seconds.

Read More
Bernard -
March 23, 2012
A:

Bernard, the oven gas valve and the oven ignitor are wired in series. Voltage is provided to them simultaneously by the oven control. The ignitor draws the current and heats. As the ignitor gets hot the resistance of the ignitor changes and the amp draw changes also. When the amp draw of the ignitor reaches 3.4-3.6 amps, the gas valve opens. Since the ignitor is staying on and the gas valve is cycling off and on, the problem is almost certainly in the ignitor. I hope this makes sense to you. If you have questions, reply.

Read More
Jimmy K -
Sears Technician
March 26, 2012
A:

Jimmy K, thanks for your expert advice. I changed the ignitor and so far so good, it's working great!! Thanks, Bernard.

Read More
Bernard -
March 31, 2012
A:

I am glad you got the oven working. Thanks for using Manage My Life.

Read More
Jimmy K -
Sears Technician
April 02, 2012