Model #66592022101 KENMORE Free Standing, Electric

  • Cooktop
    3 Results
  • Door
    3 Results
  • Chassis
    3 Results
  • Control Panel
    3 Results
  • Drawer And Broiler
    3 Results
Find part by diagram >

Question and Answers

Q:

Logiclean Self Clearing Cycle- error message E1-F5- 66592022101 Kenmore Range

A:

Thank you for choosing SearsPartsDirect.com and being a valued member.  I can certainly understand how frustrating it can be when your range displays an error code.


F5 E1-Door latch not operating.

1. If door latched
A) Disconnect power from unit.
B) Check wires and connectors from control to door switch, then from door switch to
control. If no damage to wires and all connectors okay, proceed to step C.
C) Replace door switch.
D) Reapply power.
E) Press CANCEL. Program and start the Clean mode. Observe for 1 minute to ensure
that operation is normal.
2. If door not latched
A) Disconnect power from unit.
B) Check wires and connectors from control to latch switch then from latch switch to
control. If no damage to wires and all connectors okay, proceed to step C.
C) Repeat steps A) and B) for door switch.
3. Measure door switch (door open = switch open small low voltage terminals).
4. Measure latch switch (unlatch = switch open, oven light contacts are closed).
5. If corrections are made in any step, reconnect power to control. Press CANCEL. Program
and start the Clean mode. Observe for 1 minute to ensure that operation is normal.
6. If failure remains, disconnect power and replace control.

You can also visit searpartsdirect.com for parts, diagrams, and repair information.

If you do not feel confident repairing this problem yourself, then you can have it repaired at your home by a Sears technician. Here is a link for the website: Sears Home Services .

Thank you for your question. Have a great day. 

Read More
Natasha12 -
Sears Technician
December 11, 2014
Q:

What does the fault codes E-1 and F-1 indicate on my Kenmore range?

A:

The "F1-E1" fault codes are indicating an EEPROM checksum failure in the electronic oven control board.

  1. Disconnect the power to the range by disconnecting the power supply for longer than 30 seconds.
  2. Re-apply power and observe for longer than 1 minute.
  3. If the failure remains, replace the electronic oven control board.

I recommend calling a service technician to diagnose and repair your range.

Read More
Joey S -
Sears Technician

Top Parts