Error Code:



Question and Answers


Why does the burner on my gas dryer model 41759012890 only stay on for 10 sec?


The first thing to do is to disconnect the vent hose from the back of the dryer. Run the dryer and see if the flame stays on longer. There should be air blowing out the dryer vent. Make sure that the laundry room is ventilated when you run this test. A gas dryer should always be properly vented to the outside of the home. Reconnect the exhaust vent to properly vent the dryer to the outside of the home following this temporary test.

A restrictive vent is the most likely cause of this. If the burner stays on longer then your vent is restricting the air flow and would have to be checked.

If the burner does not stay on longer and there is air flow from the dryer exhaust vent then the problem would be an internal component such as the coils on the valve or the valve itself or even one of the thermostats.

The console, top and front panel need to be removed to check these parts and I recommend a technician do this.