Q:

What would cause my fan to not run, it's not stuck?

A:

I added two (2) images with the wiring diagram so that you can see the fan electrical circuit. In order to diagnose the failure a volt/ohm meter will be needed.

A technician would most likely check the voltage supply at the evaporator fan motor first. The power source to the fan motor and compressor are the same. The voltage is supplied to the compressor and the fan motor from terminal 4 on the defrost timer. If the compressor is running the defrost timer is OK. NOTE: Your refrigerator does not have a condenser fan motor as the wiring diagram indicates unless it does not have a condenser coil mounted on the rear of the refrigerator. If the condenser coils are located under the refrigerator then it would use a condenser fan.

Most likely it has failed fan motor or a loose wiring circuit to the fan motor. Evaporator fan motor part# 5304445861.

Read More
Joey S -
Sears Technician
September 16, 2008