Question and Answers

Q:

How can I stop water from accumulating on the top shelf of my Kenmore refrigerator?

A:

Everyday when your refrigerator goes through the automatic defrost cycle the water should drain out to the bottom into the drain pan. Something like this is usually caused by a blocked defrost drain #17. I recommend removing the rear panel in the freezer & checking the defrost drain trough. You can use hot water to de-ice & flush out. Be sure to check that the doors seal securely when closed.

Read More