Question and Answers


refrigerator not cold enough - it runs for about 3 min. every 5 min. It will hold 40 degrees but no colder. Its a kenmore model no. 253.61112104


Short cycling on and off like this indicates a defective thermostat. Make sure the sensing tube of the thermostat is not kinked. To check it, the control housing will need to be dropped down. Be sure to disconnect power from the unit first. If the tubing is kinked, straighten it out. It may make the difference needed to run longer. If the unit ran continuously, then it could be a problem in the seal system, the compressor or a defrost problem. The thermostat # 5304421256 is available at SearsPartsDirect . If you need more assistance, please resubmit your question, with additional details.

Safety Notice: Be sure to disconnect the appliance before performing any troubleshooting procedures. If you are not comfortable with doing any voltage checks or repairs that might be recommended, please contact a local service provider for repairs. Be aware that there could be sharp edges inside the appliance that could cause cuts or other injuries to yourself or others.