Can there be a gas leak in the thin pipe at the bend before reaching the pilot outlet on a gas hot water heater?


Yes it's possible for the aluminum tubing to crack and leak gas. If flame is shooting out of the pilot tubing instead of at the pilot assembly shut the gas off to the water heater until the pilot tubing has be replaced. The model number you submitted is not a complete model number. If the complete model number is 153.331440, 153.331441 then the part number of the pilot tubing is #9000278. If the model number is 153.331442, 153.331443 or 153.331444 then the burner assembly will need to replaced, part #9003515.

Read More
Joey S -
Sears Technician
April 15, 2010