Q:

Drum Stoped Turning 11098572210 Kenmore Electric dryer

A:

More than likely the thermal fuse has blown and needs replaced. This can be tested by disconnecting the wires to the thermal fuse and temporarily taping them together with electrical tape to see if the drum starts turning. Make sure you turn the brakers off while doing this.  Before this all done check to see if the belt is broken.

Read More
Jeffrey8673 -
Sears Technician
September 11, 2015
A:

Where is the belt located on this dryer ?

Read More
Carlton -
September 11, 2015
See more answers
Q:

Is there anything that needs to be added to the exhaust of my portable dryer to use it inside the house?

A:

There is nothing that needs to be added to your exhaust on this portable dryer if you are using it inside without an external exhaust duct connected to it. The dryer will exhaust directly into the room.