Error Codes

Error Code:

Condition:

Check/Repair:

Question and Answers

Q:

Why does my Kenmore dryer model 96292110 not start?

A:

When an electric dryer does not run and the timer lights up the most likely cause is an open thermal fuse.

The door switch can click but still be bad but I recommend checking the thermal fuse first.

The image below shows how to access the thermal fuse. Remember to unplug the dryer so no voltage is present while checking the thermal fuse.

The thermal fuse should have 2 blue wires on it. The operating thermostat is next to it and will have a red and a red/white wire on it.

If you have access to a volt/ohm meter you can check continuity across the fuse. If the circuit is open then the fuse is bad.

The part number for the fuse is 3390719 and is available from the following link: Sears PartsDirect .

I hope this information is helpful resolving your problem but if you have any additional questions then submit another question with additional details for further assistance.

Read More
Fred M -
Sears Technician
March 28, 2009
A:

Still good advise in 2013! Worked like a charm.

Read More
Tim -
April 07, 2013