Why won't my Kenmore gas dryer heat?


The Blue wire you found disconnected is not a ground wire, it is the wire supplying the voltage to the gas valve assembly and related parts. The dryer will not heat if the blue wire is disconnected. I added the wiring diagram in the image below so that you can see where to connect the blue wire. The blue wire was likely connected to the thermal fuse (key#39) as shown in the image. The thermal fuse is mounted to the back of the blower housing.

NOTE: Disconnect the power cord before reconnecting the blue wire and then your dryer will likely heat again.

Read More
Joey S -
Sears Technician
January 28, 2010