Q:

have kenmore coldspot mod 10689489996 freestanding icemaker. am refergeration tech unit not making ice. all electric ,compressor,pump,ect check ok.

A:

Now that summer is here its time to get this ice maker working so you can have nice cold drinks. While you are waiting on an expert to answer your question, I found a great link in the Manage My Life website. I have attached the link below so you can get this ice maker going. Have a nice day!

Read More
Dezeray -
June 25, 2012
A:

Thank you for your question. If everything is working but there is no ice forming on the evaporator, it would lead to a sealed system problem. There have been no issues of refrigerant leaks in these ice machines. This could be a low charge, the compressor may not be pumping properly or the hot gas valve may be stuck and could be causing this problem. This unit should take 6.5 ounces of 134a refrigerant. The refrigerant charge will also be listed on the model and serial tag. I hope this will help you.

Read More
Scott D -
Sears Technician
June 27, 2012
A:

I WOULD NOT BUY THIS UNIT. IT COST TO MUCH TO PURCHASE AND TO REPAIR IT.

Read More
Glenn -
July 30, 2014
See more answers
Q:

Kenmore free standing ice maker #10689489996 freezes up

A:

Thank You for choosing Sears PartsDirect.com. I regret to hear that you are having issues with your icemaker and do understand your frustration. Glad to help out. Im looking at your model number 10689489996 and to check the grid, disconnect the power first. Now, pull the grid out (see image) and if you have a meter, (click on the image to enlarge) the resistance can be checked. With the harness disconnected check across the pins and it should read 4 to 5 ohms of resistance. If there is no resistance reading, the complete grid # 2313637 will need to be replaced. If this checks ok, the voltage will need to be checked to the grid. Reconnect the harness and turn the unit back on. Now check to see if 8.5 volts is being supplied to the grid. Be very careful making this check. If there is no voltage there, the transformer # 2185657 will need to be replaced. If you do not feel confident repairing this problem yourself, then you can have it repaired at your home by a Sears technician

I have included a link to our PartsDirect page where you can purchase the part you need to complete your repair. Just click the blue link above to be taken to the page. If you have further questions please resubmit your question for further information.

 

Thank you for choosing Sears PartsDirect.com.

Read More
Sherman_G_Wallace -
Sears Technician
May 23, 2014
Q:

Ice maker freezes up 10689489996 Kenmore Ice maker free standing

A:

Thanks for your question- we see that no one from the community responded.  If you still require assistance on this topic, please resubmit your question with any updated information and we will have one of our experts take a look.  Also, we have updated our site to include information regarding common repairs and diagnosis, which can be found here: www.searspartsdirect.com/repair-help.html.  If you are looking for your owner’s manual, it can be found here: http://www.searspartsdirect.com/partsdirect/user-manuals.  Thanks for visiting SearsPartsDirect.com.

Read More
Natasha12 -
Sears Technician
May 13, 2014