Q:

Restriction in kenmore coldspot refrigeration tubing

A:

Managemylife.com is a great place to find the answers to just about anything, especially on appliances. Here is a similar question that an expert responded to that may help you. The expert will take up to two business days but usually sooner to respond to your inquiry.

Read More
James -
January 17, 2012
A:

Thank you for the link. However they just recommend flushing the lineset, which in my experience usually is not enough to clear it. I'm specifically asking if it is possible to feed a new cap tube through without taking the entire fridge apart.

Read More
Peter James -
January 17, 2012
A:

Thank you for your question.

The only thing you can do is try to blow out the restriction with nitrogen. If you think it cleared, install a new filter/dryer before closing the system up. Once it is closed, you can either vac the system down or sweep charge it before recharging the system. If the cap tube does not clear, it is not repairable.

Thank you for using Manage my life.

Mark T.

Read More
Mark T -
Sears Technician
January 19, 2012