Model #10658526700 KENMORE Side-by-Side Refrigerator

  • Cabinet Parts
    3 Results
  • Refrigerator Liner Parts
    3 Results
  • Refrigerator Shelf Parts
    3 Results
  • Freezer Liner Parts
    3 Results
  • Motor And Ice Container Parts
    3 Results
  • Refrigerator Door Parts
    3 Results
  • Freezer Door Parts
    3 Results
  • Dispenser Front Parts
    3 Results
  • Unit Parts
    3 Results
  • Air Flow Parts
    3 Results
  • Control Parts
    3 Results
  • Icemaker Parts, Optional Parts (not Included)
    3 Results
Find part by diagram >

Error Codes

Error Code:

Condition:

Check/Repair:

Question and Answers

Q:

Fridge Repair 10658526700

A:

Thanks for the inquiry and for using SearsPartsDirect.com.
I am sorry to hear of the issue you are having with the refrigerator and freezer temps, I know how frustrating that is to have occur.
Since the unit appears to be somewhat cooling, I presume the compressor at the back bottom of the unit is running. Have you checked the operation of the condenser fan motor back there to see if it's running? How hot is the compressor? 
Since you've replaced the thermostat and it didn't appear to help the situation, I am suspecting that the compressor is in need of a recharge and that is the most logical reason why it's not cooling properly. The freezer supplies the chilled air via the compressor, which in turn circulates that chilled air to the refrigerator when the thermostat kicks in. Since the freezer is also warming but the compressor is running, I suspect a compressor issue. If the compressor was not running, then I would suspect the start relay and overload. 
It might be best to have a service technician come out and help with the diagnosis and repair. If the compressor needs a charge, it would be best left to a technician. 
If you would feel more confident have a Sears Home Service technician help assist with the diagnosis/repair, you can call 1-800-349-5071, or click here to be directed to the page to set up service.
Hope this helps and thanks for using SearsPartsDirect.com. We appreciate your business. 

Read More
Jeff Wallace Sr -
Sears Technician
June 12, 2014
Q:

Frost on Ice Dispenser 10658526700 Kenmore Side by side refrigerator

A:

I know that it can be very frustrating to have issues with your ice dispenser. The issue is either the ice door is not sealing properly or there is warm moisture laden air leaking by the wiring harness into the ice chute. The images below is the sealing process for the wiring harness in the dispenser. To seal the harness, the front cover (key#23 of image 2) will have to be removed.

The front cover will come off by removing the drip tray. Pry out starting at the bottom corners with a plastic putty knife or flat blade screwdriver.

Frost underneath the In-Door Ice Bucket

1. Check and use Permagum™ or silicone to seal wiring harness grommet in the top left of the ice and water dispenser housing. See Fig. 13.

2. Visually check ice chute door for proper closure.

a. If ice chute door does not close properly, order Ice Door Kit 46/106-8201649.

b. If ice chute door hinge tab is broken, order kit 46/106-8201756.

If you don't feel comfortable doing this yourself, please click on the link to schedule service: Sears Home Services. Click on "Get Started" and follow the directions, click on the red "NEXT" button to continue. I hope this helps. Please feel free to let me know if you need further assistance. We are always here to help. Thank you for using ManageMyLife.com.

Read More
AnneJ -
Sears Technician
September 02, 2013
Q:

10658526700 Kenmore Side by side refrigerator, door question

A:

I know this type of information can be very helpful for you to have. While you are waiting for your expert answer, I did some research on the unit. I was unable to locate information that would be helpful with regards to your question at this time. Your expert will answer within 24-48 hours with detailed information. Thank you for using Manage My Life.

Read More
Jackie S -
November 07, 2011
A:

Thank you for your question. I can understand your concern. Yes, there should be a chute door. If it's not there, it will create the problem you're experiencing because of the warm outside air, constantly entering the chute and freezer. The door mechanism assembly is # 8201649 but if the hinge tabs on the housing breaks, there is a kit # 8201756 that will be needed. This kit will come with instructions. Yes, this should be an easy fix for a technician. These parts are available at SearsPartsDirect . If you would like more assistance, reply to this thread and I will be glad to assist you further.

Read More
Scott D -
Sears Technician
November 08, 2011
See more answers