Error Codes

Error Code:

Condition:

Check/Repair:

Question and Answers

Q:

ice maker not filling 10655386400

A:

Thank you for choosing Sears, I will be more than happy to assist you with your

Based on the information listed, it indicates the icemaker will need to be replaced. However, it's possible the water valve could be weak and not opening but it's not as likely. What happens is, there is a slight voltage drop through the icemaker to the valve and sometimes if the valve gets weak, it won't open but this does not happen very often. If there is a humming sound from the valve when the icemaker cycles but no water is flowing, it would indicate the valve needs to be replaced.

I hope you found this information helpful. Thank you for choosing Sears Parts Direct. We appreciate your business. Have a great day.

Read More
Samantha A -
Sears Technician
November 06, 2014
A:

water is flowing, but it leaks from the bottom of ice maker. Also seems to be splashing as it leaves the water spigot as if obstructed. The leaking would explain why water was in the ice bin and had refrozen.

Read More
JAMES -
November 07, 2014
See more answers
Q:

Refrigerator model 10655386400 how to remove & install auger substitute part w10422851?

A:

Managemylife.com is a great place to find the answers to just about anything, especially on appliances. I did some research for you and found an expert answer to a similar question that may help until your expert can respond to your specific question. The link is attached below. If you do decide to schedule service and have a qualified technician help you, I have also attached a link to Searshomeservices. I hope these links provided assist you.

Read More
James -
January 18, 2012
A:

The link James sent you gives you an idea of the problems with replacing the auger. We do not have instructions for removing and replacing the auger. This work is usually done by a technician and they don't need instructions.

I advise you to look at the video Scott D sent the customer and see if it makes sense to you. You might want to consider buying a complete ice bucket instead of replacing the auger.

The complete ice container is part number W10312301, and the price is $128.75.

Read More
Jimmy K -
Sears Technician
January 19, 2012
See more answers
Q:

Why does water continues to flow through the refrigerator dispenser even after stopping it?

A:

When you release the lever and water continues to flow can be caused from a couple of reasons:

  1. Air in the water line
  2. Air mixed in with the incoming water
There is a simple test to determine if the air is in the water or trapped in the line. When you get some water from the dispenser using a clear glass set it on the table. Watch it for couple of minutes and if you see bubbles in it that means the air is in the water. You will need to have the water company out to check your water supply for this. If nothing happens then the air is trapped in the line. Air trapped in the water line can be difficult to remove. Sometimes running a lot of water through it will eventually remove it. If not you may have to remove the reservoir and empty it to get it out. If you do this first disconnect the refrigerator from the wall outlet and then turn the water supply valve off. You can now disconnect the reservoir and remove it. Be careful there will be some water spillage. Empty the reservoir and reconnect it. This should take care of the problem. If you need more assistance you can resubmit your question with more details.

Read More
Scott D -
Sears Technician
A:

kenmore refrig Mod # 106.55386400 when the arm is down for ice cubes water must over flow and freeze, because when I open the freezer there is frozen icicles all the down the the bottom of freezer and on top of all the food on each shelf (a layer of ice) Also when the wtr disp is pressed (from exterior), the flow doesn't stop?!!

Read More