Question and Answers


Why won't my air compressor pump up past 60-70 psi before shutting off and not restarting until 15-30 minutes later?


I do not have enough details but it sounds like the motor is overheating and shutting off on the motor thermal overload. Once the motor cools down the thermal overload resets and it will run again.

You did not indicate if you were to drain all the air out of the tank if it would restart. I will assume it will not. I must also assume that you are not using an extension cord that is too long or too small. The failure is either a low voltage supply or a bad motor providing the there is not a friction problem within the compressor.

Read More
Joey S -
Sears Technician
April 15, 2009